Basic parameters | |
Diameter measuring range |
0.7…70 mm |
Scanning frequency |
200 1/sec |
Accuracy |
± 7.5 μm - for min diameter ± 20 μm - for max diameter |
Indication |
|
Display of the measured and set diameter, deviation from the set value |
- Remote terminal with graphic touch display 3.5" or 4.3" - Built-in digital indicator on the front panel of the measuring head (measured diameter only) |
Max cable lehght for remote terminal |
100 m |
Indication of cable exit outside the measuring zone |
LED indicator on the measuring head |
Interfaces |
|
Analog outputs |
Output 1: ± 10 V, Output 2: 0...10 V Two scalable analog outputs of the deviation from the nominal. Can be used in the automatic diameter stabilization system.
Absolute value of diameter 4..20mA (optional)
|
Relay outputs |
Two relay ouputs 220 V 1 А (H and L diameter limits alarm) |
Communications
|
RS485 Modbus, Profibus (optional) |
Power supply |
|
Voltage |
230 V ± 10 % |
Frequency |
50 Hz ± 5 % |
Power consumption |
5 VA (measuring head) 5 VA (remote terminal) |
Complementary parameters |
|
Measuring zone |
80 х 100 mm |
Body material |
corrosion resistant duralumin |
Degree of protection |
IP20 (measuring head) IP40 (remote terminal)
For particularly severe operating conditions (for example, measuring the diameter of the wire during drawing), air channels can optionally be added to the measuring head to purge and create an air barrier from dust, dirt, emulsion and other contaminants entering the device.
This will require the compressed air class 2.4.3. according to ISO 8573-1: 2001) with an excess pressure of 0.05 MPa (0.5 bar). |
Operating temperature |
0…+45 °С |
Overall dimensions (L х W х H) |
550х192х58 mm (measuring head) |
Weigh |
4 kg (measuring head) 1 kg (remote terminal) |
Options |
|
Інтерфейс Profibus |
External Profibus DP converter. The address space corresponds to Sicora meters, which allows quick replacement. |
Mounting rack |
It reduces installation time on the line. Electrical installation is completed.
|
Air channel |
For use in rooms with high dust content: drawing lines, talcum machinery, etc. Significantly increases the work interval between maintenance. Requires advanced air quality preparation. |
Reference calibers |
A set of three calibers of different diameters is designed to check the accuracy of measuring head. |